Rio Blanco County, COCompliance reporting portal
Demo · made-up dataOpen the pro appChange county
← Septic review queue

Septic maintenance (pump-out) · 7867 Ridgeview Dr

Approved

Filed Nov 8, 2017 by Hayden Ramirez, Patriot Wastewater · filed from phone

Report

Date of service
Nov 8, 2017
Tank size
1250 gal
Compartments
1
Gallons pumped
1289 gal
Sludge depth
30 in
Scum depth
9 in
Baffles in good condition
No
Effluent filter
Cleaned
Lids and risers secure
Yes
Disposal site
Permitted land-application site
Repair needed
Yes
Repair needed: describe
Distribution box settled
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 103-82-01100
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

7867 Ridgeview Dr
Owner: Drew Benton
Parcel 103-82-01100