Septic maintenance (pump-out) · 637 Hickory Ct
ApprovedFiled Jul 12, 2024 by Quinn Kessler, Clearwater Septic Service · paper form read in and confirmed by staff
Report
- Date of service
- Jul 12, 2024
- Tank size
- 750 gal
- Compartments
- 2
- Gallons pumped
- 672 gal
- Sludge depth
- 33 in
- Scum depth
- 2 in
- Baffles in good condition
- No
- Effluent filter
- Replaced
- Lids and risers secure
- Yes
- Disposal site
- Permitted land-application site
- Repair needed
- No
- Photos
- None
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file and current for septage hauler
- All required fields present
- Address matches parcel 085-26-01023
- Sludge is over a third of a typical tank depth; check for system failure.
- Baffles reported damaged; county may require repair.
- No photos attached.
- Result: passing. Next due date resets when approved.
Decision
Approved by J. Staff. The property's next due date is set and the owner gets a receipt.