Clear Creek County, COCompliance reporting portal
Demo · made-up dataOpen the pro appChange county
← Septic review queue

Septic maintenance (pump-out) · 6819 Cedar Hollow Dr

Approved

Filed Jul 21, 2019 by Rowan Kessler, Patriot Wastewater · paper form read in and confirmed by staff

Report

Date of service
Jul 21, 2019
Tank size
1000 gal
Compartments
2
Gallons pumped
953 gal
Sludge depth
25 in
Scum depth
7 in
Baffles in good condition
Yes
Effluent filter
Cleaned
Lids and risers secure
Yes
Disposal site
Regional wastewater plant
Repair needed
Yes
Repair needed: describe
Cracked lid
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 019-90-01060
  • Sludge is over a third of a typical tank depth; check for system failure.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.

Property

6819 Cedar Hollow Dr
Owner: Parker Okafor
Parcel 019-90-01060