Yolo County, CACompliance reporting portal
Demo · made-up dataOpen the pro appChange county
← Septic review queue

Septic maintenance (pump-out) · 5637 Sycamore Dr

Approved

Filed Dec 3, 2020 by Morgan Calloway, Northstar Wastewater · filed from phone

Report

Date of service
Dec 3, 2020
Tank size
1250 gal
Compartments
2
Gallons pumped
1098 gal
Sludge depth
34 in
Scum depth
3 in
Baffles in good condition
No
Effluent filter
None present
Lids and risers secure
No
Disposal site
Permitted land-application site
Repair needed
No
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 113-97-01205
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • Unsecured lids are a safety hazard.
  • No photos attached.
  • Result: passing. Next due date resets when approved.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

5637 Sycamore Dr
Owner: Blake Kessler
Parcel 113-97-01205