← Septic review queue
Septic maintenance (pump-out) · 2810 Pine Knoll Ct
ApprovedFiled Oct 25, 2022 by Parker Marsh, Clearwater Wastewater · paper form read in and confirmed by staff
Report
- Date of service
- Oct 25, 2022
- Tank size
- 1500 gal
- Compartments
- 2
- Gallons pumped
- 1290 gal
- Sludge depth
- 33 in
- Scum depth
- 7 in
- Baffles in good condition
- No
- Effluent filter
- Cleaned
- Lids and risers secure
- Yes
- Disposal site
- County treatment plant
- Repair needed
- Yes
- Repair needed: describe
- Outlet baffle missing
- Photos
- 2 attached
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file and current for septage hauler
- All required fields present
- Address matches parcel 087-28-01016
- Sludge is over a third of a typical tank depth; check for system failure.
- Baffles reported damaged; county may require repair.
- Result: needs follow-up. The property stays on the overdue list until a passing report arrives.
Decision
Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.
Property
2810 Pine Knoll Ct
Owner: Alex Lindqvist
Parcel 087-28-01016