Napa County, CACompliance reporting portal
Demo · made-up dataOpen the pro appChange county
← Septic review queue

Septic maintenance (pump-out) · 4148 Pine Knoll Rd

Approved

Filed Jul 27, 2024 by Cameron Okafor, Heritage Wastewater · filed from phone

Report

Date of service
Jul 27, 2024
Tank size
1000 gal
Compartments
2
Gallons pumped
900 gal
Sludge depth
29 in
Scum depth
2 in
Baffles in good condition
No
Effluent filter
Replaced
Lids and risers secure
Yes
Disposal site
County treatment plant
Repair needed
Yes
Repair needed: describe
Outlet baffle missing
Photos
2 attached
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 055-49-01231
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

4148 Pine Knoll Rd
Owner: Casey Ashby
Parcel 055-49-01231